Intelligent Breaker Single Bus Panel
Features 12 hydraulic-magnetic breaker positions, 200A continuous bus rating, integrated TCP/IP Ethernet web server, individual output current monitoring, and remote power cycling.
In mission-critical telecom, public-safety radio networks, and remote industrial shelters, power availability is non-negotiable. A Single Bus DC Power Distribution Panel serves as the central hardware point of entry and current division between a unified DC power supply (rectifier system or battery bank) and multiple downstream load devices.
Unlike basic unmanaged fuse blocks or traditional AC power distribution units (PDUs), an engineering-grade Single Bus DC Distribution Panel channels up to 200 continuous amperes across a heavy-gauge internal copper busbar. It splits this primary supply into individually protected output branches featuring hydraulic-magnetic circuit breakers or specialized GMT/ATO fuses. This architecture ensures that a short-circuit fault or current spike on one radio module or network switch trips only its local branch, isolating the fault without dropping the main DC power bus or compromising adjacent critical hardware.
Choosing between Single Bus and Dual Bus DC power distribution depends heavily on your site's redundancy framework, equipment power supply architecture, and budget parameters.
| Design Criteria | Single Bus DC Distribution Panel | Dual Bus DC Distribution Panel |
|---|---|---|
| Primary Input Topology | Single high-capacity DC input feed (up to 200A total bus current). | Two electrically isolated DC inputs (Bus A and Bus B, e.g., 100A + 100A). |
| Best Fit Applications | Sites powered by a single rectifier rack, single battery string, or single-power-supply radio hardware (LMR repeaters, microwave backhaul). | Mission-critical core switches, routers, and servers equipped with dual redundant (A/B) internal DC power supplies. |
| Channel Density per 1U | Higher output density per bus; up to 12 or 18 branch outputs tied to one common voltage rail. | Divided output density (e.g., 6 positions on Bus A, 6 positions on Bus B). |
| Cabling Complexity | Streamlined, low-complexity cabling. Single set of primary DC input studs simplifies rack wiring. | Requires dual sets of heavy-gauge input cables and separated wire routing paths for A/B channels. |
| Cost & Space Efficiency | Maximum cost-per-port value; ideal for high-density edge sites requiring managed distribution. | Higher initial hardware investment; optimal for Tier-3/Tier-4 data centers and central offices. |
| Fault Isolation Boundary | Branch-level isolation; breaker/fuse trips isolate local device faults while keeping main bus active. | Bus-level and branch-level isolation; entire Bus A can fail or undergo maintenance while Bus B runs uninterrupted. |
Engineered for high reliability, precise load management, and seamless integration into modern network operations center (NOC) software platforms.
Features 12 hydraulic-magnetic breaker positions, 200A continuous bus rating, integrated TCP/IP Ethernet web server, individual output current monitoring, and remote power cycling.
Designed for low-to-medium power loads utilizing GMT or ATO/ATC high-density fuses. Offers 100A-200A bus capacity with individual fuse status monitoring and email alarm alerts via SNMP.
Ultra-compact DIN-mount DC distribution unit designed for cabinet enclosures, outdoor pole-mount small cells, and SCADA industrial automation control panels requiring 12V/24V/48V bus distribution.
Review standard electrical ratings, environmental tolerances, and firmware capabilities across the ICT Single Bus portfolio.
| Electrical & Mechanical Parameter | Specification & Performance Range |
|---|---|
| Nominal Operating Voltages | 12 VDC, 24 VDC, or 48 VDC (Universal voltage range: 10 VDC to 60 VDC continuous). |
| System Bus Rating | 150A to 200A continuous total current rating @ +60°C ambient temperature. |
| Number of Output Channels | 12 or 18 individually protected output positions (Breaker or Fuse variants). |
| Maximum Output Rating per Channel | Up to 25A or 30A per breaker position; 15A per GMT fuse position. |
| Circuit Protection Type | Field-replaceable hydraulic-magnetic circuit breakers or GMT / ATO / ATC fast-acting fuses. |
| Monitoring Hardware | High-precision internal shunt resistor array per output channel; true RMS current & voltage sensing. |
| Network Interface & Security | 10/100Base-T Ethernet RJ45 port; supports HTTPS, SSL/TLS, SNMP v1/v2c/v3, NTP, and DHCP/Static IP. |
| Remote Load Control | Independent channel ON/OFF control, remote power cycling, automated load shedding per channel. |
| Operating Temperature Range | -30°C to +60°C (-22°F to +140°F); designed for unconditioned remote shelters. |
| Chassis Form Factor & Mounting | 1U standard 19-inch rack mount; optional 23-inch rack adapter brackets included. |
Dispatching a field technician to a remote mountain tower or isolated broadband site just to toggle a frozen radio breaker costs hundreds of dollars in truck rolls and incurs costly network downtime.
ICT Intelligent Single Bus DC Power Distribution Panels eliminate unnecessary dispatch visits by embedding a feature-rich TCP/IP web server directly into the chassis hardware. Network Operations Center (NOC) personnel gain complete control over distant site infrastructure through any standard HTML5 browser or enterprise Network Management System (NMS).
Avoid common installation failures, nuisance tripping, and excessive voltage drops by following our step-by-step engineering sizing methodology.
Per standard electrical guidelines (such as NEC Article 210), DC continuous loads must not exceed 80% of the maximum continuous bus rating or individual breaker capacity.
Calculation Formula:
Target Bus Rating = (Sum of Continuous Loads × 1.25) + Sum of Non-Continuous Peak Loads Low-voltage DC systems (especially 12V and 24V networks) are highly susceptible to voltage degradation over long cable runs. Maintain voltage drop below 2% to protect sensitive electronics.
Voltage Drop Formula:
V_drop = (2 × Length (ft) × Current (A) × Cable Resistance (Ω/kft)) / 1000 Choose Hydraulic-Magnetic Breakers for inductive motor loads, radios, and high-current devices that demand precise trip curves independent of ambient temperatures. Use GMT Fuses for ultra-high-density, low-current alarm panels and telecom telemetry links.
Define two distinct battery voltage thresholds: Disconnect Level 1 for non-essential monitoring gear, and Disconnect Level 2 (Main LVD) to protect the battery bank from destructive deep discharge below 1.75V per cell.
See how system integrators and telecom operators utilize ICT Single Bus DC Distribution Panels to secure zero-downtime performance.
County 911 dispatch networks deploy ICT Single Bus panels to power 48V P25 voice repeaters, microwave backhaul links, and antenna combiners with full SNMP alarm visibility.
Wireless Internet Service Providers standardise on ICT Intelligent panels to monitor power draw per sector antenna and remotely power-cycle locked-up PoE injectors.
Remote pipeline valve stations utilize 24V ICT Single Bus panels operating off solar-battery systems to maintain persistent remote communication and automated low-voltage disconnect.
Key technological and purchasing shifts transforming low-voltage DC infrastructure over the next decade.
Modern procurement directors are moving away from passive "dumb" fuse boxes toward software-defined DC distribution units capable of predictive maintenance analytics, automated energy management, and REST API software integration.
Remote edge sites are increasingly powered by hybrid solar-wind-lithium battery systems. Modern single bus panels must support wide input voltage fluctuations and communicate with intelligent battery management systems (BMS).
As power equipment connects directly to corporate IP networks, security standards have escalated. Next-generation buyers require encrypted HTTPS, SSL/TLS certificates, zero-trust network access, and secure SNMPv3 authentication.
Network operators face aggressive space constraints and sustainability targets. Enterprise specifiers prioritize 1U ultra-compact panels offering higher thermal efficiency, minimal standby loss, and recyclable, rugged metal construction.
Founded in 1986, Innovative Circuit Technology (ICT) brings nearly four decades of specialized DC power design and manufacturing experience to your mission-critical deployment.

We do not make consumer gadgets. We focus 100% on mission-critical industrial, telecom, and land mobile radio DC power conversion and distribution.

Our web interfaces, SNMP stacks, and security firmware are developed and maintained in-house, ensuring traceable code, fast security patches, and lifetime updates.

Specified globally for emergency 911 dispatch centers, military communications, railway signals, and tier-one telecom backhaul networks.

All engineering, assembly, quality testing, and customer support are performed at our headquarters in Langley, BC, Canada—offering fast lead times and direct engineering access.
Proven performance engineered into every chassis since 1986.
Answers to common technical, installation, and procurement questions asked by engineering teams and AI search tools.
Need assistance sizing your Single Bus DC Distribution Panel or configuring automated load shedding? Speak directly with our North American application engineers.
Inquire NowLocate global stocking distributors and qualified system integrators in your region for immediate local currency purchasing and technical support.
Find a Distributor