+1 877 930 0717 (NA Toll Free) Langley, BC, Canada DC Power Engineering Since 1986
High-Availability Power Platforms

DC Power Systems

Engineering Excellence Since 1986

Intelligent Modular DC Power Systems for Critical Infrastructure

ICT DC Power Systems deliver intelligent, scalable, and ultra-reliable DC power conversion, battery management, and load distribution for mission-critical networks across telecom, wireless broadband, land mobile radio (LMR), and industrial utility sectors.

Engineered and manufactured in North America, our rack-mount DC power shelves support nominal bus voltages of 12 VDC, 24 VDC, and 48 VDC. Featuring hot-swappable current-sharing rectifiers, remote Gigabit Ethernet HTML/SNMP monitoring, and optional integrated dual-voltage converters, ICT power systems ensure continuous 24/7 uptime for unassisted remote sites worldwide.

  • Hot-Swappable N+1 Redundancy: Scale output capacity dynamically while maintaining live load operation.
  • Advanced Lithium-Ion Integration: Direct RS-485 MODBUS communication with modern Battery Management Systems (BMS).
  • Integrated TCP/IP Remote Management: Real-time voltage, current, and circuit control via HTTPS and SNMP v1/v2c/v3.
  • Multi-Voltage Dual Bus Formats: Primary 24V or 48V bus with optional auxiliary 12V or 24V DC-DC output conversion.
ICT MPS Ultra 2 Hot-Swap DC Power System Shelf
Product Fleet

Explore ICT Modular DC Power Systems

Selecting the right power architecture starts with understanding your load profile, battery autonomy requirements, and rack-space availability.

MPS Ultra 2 DC Power System
2RU High Density

MPS Ultra 2

The flagship MPS Ultra 2 provides up to 12,000 Watts of output power in a compact 2RU chassis. Designed for high-capacity site demands, it accepts up to eight hot-swappable 700W, 1000W, or 1500W power modules in 12V, 24V, or 48V DC outputs.

  • 10/100/1000 BASE-T Gigabit Ethernet web & SNMP interface
  • RS-485 MODBUS interface for direct Lithium-ion BMS communication
  • Optional Battery Management & Load Distribution Modules with remote circuit switching
  • N+1 current-sharing redundant power delivery
Modular Power Series 2 DC Power System
1RU Ultra Compact

Modular Power Series 2

Delivering up to 4,500 Watts in a space-saving 1RU enclosure, the Modular Power Series 2 accommodates up to three hot-swappable 700W, 1000W, or 1500W power modules (12V, 24V, or 48V VDC), serving high-value remote communications huts.

  • High power density suitable for shallow or restricted racks
  • Integrated TCP/IP web browser interface with SNMP monitoring
  • Automated battery disconnect (LVD) and temperature compensation
  • Optional factory-configured Load Distribution Module
Hybrid Ultra Dual Voltage DC Power System
Dual Voltage / 2RU

Hybrid Ultra

Designed for sites requiring dual DC voltage rails, the Hybrid Ultra generates up to 7,500 Watts of primary 24V or 48V DC power alongside an integrated auxiliary 12V or 24V DC-DC converter output within a unified 2RU assembly.

  • Eliminates secondary converter shelves and extra wiring complexity
  • Advanced enterprise security: HTTPS, TLS 1.3, SNMP v1/v2c/v3
  • Hot-swappable primary power modules (700W, 1000W, 1500W)
  • Precision battery monitoring and programmable load shedding
Hybrid Power Series Dual Voltage DC Power Shelf
Dual Voltage / 1RU

Hybrid Power Series

The Hybrid Power Series delivers up to 3,000 Watts of primary 24V or 48V DC output plus an auxiliary 12V or 24V DC converter output in a slim 1RU profile. Ideal for mixed-voltage radio repeaters and edge wireless sites.

  • Supports dual voltage loads in a single compact 1RU rack mount
  • Full remote telemetry, alarming, and circuit switching capabilities
  • Enterprise network security protocols (HTTPS, TLS 1.3, SNMPv3)
  • Hot-swappable module replacement for seamless live maintenance
Engineering Specifications

DC Power Systems Technical Comparison Matrix

Review output power ratings, rack dimensions, auxiliary options, and network interface capabilities across our flagship modular platforms.

Technical parameters for ICT DC Power Systems. Custom output settings and module configurations available upon request.
Model Series Form Factor Max Output Power Primary Voltage Rail Auxiliary Rail Support Network Security & Monitoring
MPS Ultra 2 2RU 19-inch Rack Up to 12,000 W 12, 24, or 48 VDC Optional LDM / BMM Gigabit Ethernet, SNMP v1/v2c/v3, MODBUS RS-485, HTTPS
Modular Power Series 2 1RU 19-inch Rack Up to 4,500 W 12, 24, or 48 VDC Optional LDM Module 10/100/1000 Ethernet, HTML Web Server, SNMP Alarming
Hybrid Ultra 2RU 19-inch Rack Up to 7,500 W 24 or 48 VDC Integrated 12 or 24 VDC Converter HTTPS, TLS 1.3, SNMP v1/v2c/v3, TCP/IP Remote Web Interface
Hybrid Power Series 1RU 19-inch Rack Up to 3,000 W 24 or 48 VDC Integrated 12 or 24 VDC Converter HTTPS, TLS 1.3, SNMP v1/v2c/v3, Embedded HTML Controller
Why Global Procurement Teams Choose ICT

Built for Uncompromised Reliability at Unattended Sites

Over three decades of specialized power conversion design ensure our systems withstand extreme grid fluctuations and ambient thermal conditions.

N+1 Redundant Reliability

Hot-swappable power modules allow live replacement without dropping critical site loads. Current-sharing architecture ensures equal thermal stress across all rectifiers.

Intelligent Remote Management

Prevent unnecessary truck rolls. Monitor bus voltage, output current per channel, ambient temperature, and battery state-of-charge remotely over standard web browsers or SNMP platforms.

North American Manufacturing

Designed, built, and tested under strict ISO quality standards in Langley, British Columbia, Canada. Direct factory technical support and fast lead times for international projects.

Procurement & Technical FAQ

Frequently Asked Questions on ICT DC Power Systems

Essential guidance for system integrators, telecommunication engineers, and global buyers.

ICT systems support 12 VDC, 24 VDC, and 48 VDC nominal buses. Output voltages across all modular shelves are adjustable to match specialized float and boost charge specifications for VRLA, AGM, Gel, and Lithium-Ion battery banks.
ICT Intelligent DC systems include an embedded web server accessible via any secure browser (HTTPS) and support SNMP v1/v2c/v3 for integration into Network Operation Center (NOC) dashboards. Engineers can remotely view system telemetry, switch individual distribution loads, reboot locked equipment, and receive real-time alarm traps.
In communication shelters housing both 48V telecom equipment and 12V or 24V radio transceivers, a Hybrid Power System delivers both output voltages from a single rack chassis. This eliminates the expense, wiring, and rack footprint of separate converter shelves while retaining unified remote Ethernet management.
Yes. All power modules within the MPS Ultra 2, Modular Power Series 2, and Hybrid Series are fully hot-swappable. Hot-swappability enables capacity upgrades or module servicing while the DC bus remains completely energized and fully supported by remaining modules or battery backup.

Request Engineering Assistance or Project Quote

Consult directly with ICT power specialists to calculate your site load budget, configure custom rack layouts, or request global commercial pricing.

Send an Inquiry